Typical Symptom:
When doing subsurface engraving with the Omni X, the actual engraved model appeared higher or lower compared with the setting in the software.
Possible Cause:
Refractive index variation of the crystal causes the laser focus point to shift.
Steps to Resolve:
Draw or import a simple pattern in ComMarker Studio.
Focus on the engraving bed. Then click Start to engrave.
Note:
If you can't see any mark on the glass, try lower or raise the laser head until you can see clear marks.
When the engraving is finished, use the Z-axis function to raise the laser head for 10mm.
Click Start to perform the engraving again.
Measure the distance between the two engraving results.
-
In the 3D Glass model, input 10mm in the Axis Depth, and the distance between the two engraving result in the Calibration Depth section.
If the issue persists, please contact Support@commarker.com and provide:
Your SN code
Your order number
A short video showing the issue
Our technical team will review your case and provide a customized solution.