*It is recommended to copy and paste the files of the USB Drive to the computer desktop or other computer disks.
1.1 Right-click "this PC", click "Manage".
1.2 Click "Device Manager", find “USBLMCV2” in Other devices.
1.3 Right-click“USBLMCV4” and "Update driver".
1.4 Select "Browse My Computer for Drivers".
1.5 Find the corresponding file in the USB drive, click “ OK ”.
1.6 Click "Install".
1.7 Click “finish” if it is successful.
1.8 it will display "BJJCZ Device" in Device Manager.
Noted:
The driver installation was unsuccessful?
*Please make sure to use the copyrighted window system, if not, please replace it with another computer.
*Please try to replace a data cable, it is recommended to use a magnetic proof cable.
*It may be a computer port problem or a computer board connection problem, please try with another computer.
2. Open the software
Open the USB folder Titan 1; open the "software11” folder. Open the software “EZCAD2”. You can enter "text", "picture" or "vector diagram" as shown in the figure below. It is recommended to select the text to test first.
3. Import the correction file
Select "Parameter (F3)", tick "Use Correct File", click , select the file ending in .cor in the USB flash drive (or have been copied to the computer disk), and click "OK".
4. Adjust the focus
Press up or down button to lift or lower the laser head until the 2 red light point overlap, which is the best focal point (the laser beam will be strongest). The measuring focal length of this machine can be found in the paper manual that came with the machine, the measuring distance is the length from the middle line of the Galvo to the surface of the engraving material. This parameter is measured manually, and each device has different focal lengths due to changes in laser sources and field lenses.
Note:
*The overlapping point should be on the marking material other than the surface of the machine.
*Red light correction before shipping. At the position where the 2 red light spots are focused, the laser emits the strongest light. However, due to transportation reasons, the focus point of the red lights you received may shift, and the focus point would not be the best focal length.
Place the test engraving material on the machine. Click "Red Light (F1)", the area shown by the red light is the marking area. Choose the parameters according to the following picture. Click "Mark (F2)" to start marking.
Note:
“Speed”, “Frequency” and “Q Pulse Width” are key parameters for marking result.
FAQs
Q1: The driver installation was unsuccessful?
*Please make sure to use the copyrighted window system, if not, please replace it with another computer.
*Please try to replace a data cable, it is recommended to use a magnetic proof cable.
*It may be a computer port problem or a computer board connection problem, please try with another computer.
Q2: The Electric lifting button can not work
*Please re-check the E-lifting wire was connected well with the supporting pole .
*Contact after-sales staff or email us.
Q3: The red light preview functions, but there is no mark or the marks are very light
*Please adjust the focal length; please debug the focal length following : “Operation Instruction”→”Step 4 “.
*Contact after sales staff or email us.
Q4: Can not find dongle, software will work at demo state
*The machine is not powered on, or the machine is not connected to the computer. Please turn it on and make sure the data cable is connected to the computer.
Q5. The size of preview and the mark is inconsistent with the software display, or preview and the mark are not horizontal or vertical but with angles.
*Import the calibration file, please refer to step 3 of the operating instructions.
*If the problem not solved, select "Parameter (F3)", select "Field". Input numbers in"Offset X","Offset Y" or “Angle”according to the actual deviation number based on the measurement with a ruler.
*If it still doesn't work, please contact after-sales staff or email us.
Q6: The red light preview is inconsistent with the actual engraving position
*Import the calibration file, please refer to step 3 of the operating instructions.
*If the problem not solved, select "Parameter (F3)", select "Other"and “Red light pointer”. Input numbers in"Offset X" and "Offset Y"according to the actual deviation number based onthe measurement with a ruler.The number can be positive or negative, the red light will change in different directions at the positive and negative values.
Q7: The preview and the shape of the mark is deformed
*Import the calibration file, please refer to step 3 of the operating instructions.
*If it still doesn't work, please contact after-sales staff or email us.
Q8: Nothing displays on canvas board when importing text or picture
*Please click the practical center button, the picture and text are in the center of the canvas.