Please follow the steps for debugging
1. Place the stainless steel test plate on the machine’s work table.
2. Turn on the machine, connect the computer with the machine.
3. Lift up or down the laser head to the best focus point according to the number in your manual.
4. Import the “TEXT” for testing , select the default parameters, and tick the “continuous part” button.
5. Press “red light” to ensure it’ll mark on the test material. Click “mark”, and the laser would be continuously marking.
6. Meanwhile, lift or lower the laser head and observe the obvious change of intensity of the laser beam. Stop when it works with the strongest laser beam.
7. At this time, loosen the screws for the two beams of the auxiliary red light.
8.Manually adjust the relative position of the red light dots to make them overlap. And tighten the screws.
Comments
0 comments
Please sign in to leave a comment.